TROUBLE-SHOOTING
Your control system is designed to provide years of trouble-free enjoyment.
However,
if
at any time your system appears to malfunction, consult the following Check List, which should help to
alleviate any problems created by operator error.
If you are still unable to solve your particular symptom, refer the situation to a qualified Pool Service Company.

NOTHING OPERATES:

1.
Check all circuit breakers at the electrical supply panel.
2.
At the W-1000, check that
SYSTEM POWER Light
is ON.
3.
Check
3
amp circuit breaker, which is located above faceplate in W-1000 Power Center.
Tripped circuit breaker is indicated by a white tab. Push to reset.
4.
If circuit breaker continues to trip, refer to a qualified Service Company.
5.
At the W-1000, turn
REMOTE CONTROLS Switch
to "OFF" position.
If the equipment can now be operated, there may be a malfunction at the Spa-side Remote Control.

FILTER PUMP DOES NOT OPERATE:

1.
At the CP-1000, push
FILTER Equipment Button,
and check that
Status Light
is ON.
2.
At the W-1000, turn
FILTER Equipment Service Switch
to "ON" position.
3.
If filter pump operates, there is a possible malfunction at the CP-1000.
4.
If filter pump does not operate, pump may require servicing.

AUX 1 DOES NOT OPERATE:

1.
At the CP-1000, push
AUX
1
Equipment Button,
and check that
Status Light
is ON.
If AUX 1 activates a pool cleaner, there will be a 4 minute delay.
2.
At the W-1000, turn
AUX
1
Equipment Service Switch
to "ON" position.
3.
If equipment operates, there is a possible malfunction at the CP-1000.
4.
If equipment does not operate, the equipment may require servicing.
5.
If AUX 1 activates a pool cleaner valve, check that cable has not been unplugged from Valve Operator

HEATER DOES NOT OPERATE:

1.
At the CP-1000, make sure that
HEAT SOURCE Switch
is in either "HEATER" or "S.PREFU position, and that
THERMOSTAT Dial
is set correctly.
2.
Check
Temperature Display.
Three dashes, or an unreasonably high temperature indicates that there is a
malfunction at the Water Sensor.
3.
Check that filter pump is running.
4.
Check the filter pressure. If filter is clogged, the heater may not be getting sufficient water flow.
5.
Inside the heater, check pilot light and heater controls. Heater must be turned on, and its own thermostat must
be turned all the way up.
6.
Heater may require servicing.

SOLAR DOES NOT OPERATE:

Note: Ambient air temperature must be approximately
5
degrees warmer than the water temperature before
solar system is activated.
1.
Check that filter pump is running.
2.
At the CP-1000, make sure that
HEAT SOURCE Switch
is in either "SOLAR" or "S.PREFU position, and that
THERMOSTAT Dial
is set correctly.
3.
Check that cable has not been unplugged from Solar Valve Operator.
4.
At the W-1000, turn
SOLAR CONTROL Switch
to "ON" position, and check to see
if
solar valve rotates.
Remember to return switch to "AUTO" position at completion of test.

SPA DOES NOT HEAT UP TO

104"

F:
1.
Inside the heater, check that thermostat is turned all the way up.
2.
High limit control on heater may need adjustiug. Refer to a qualified Service Company.
3.
At the CP-1000, if
HEATER ON Light
turns OFF before spa attains the maximum temperature of 104"
,
the
Controller may need a calibration adjustment. Refer to a qualified Service Company.