TROUBLE-SHOOTING

Your control system is designed to provide years of trouble-free enjoyment.

However, if at any time your system appears to malfunction, consult the following Check List, which should help to alleviate any problems created by operator error.

If you are still unable to solve your particular symptom, refer the situation to a qualified Pool Service Company.

NOTHING OPERATES:

1.Check all circuit breakers at the electrical supply panel.

2.At the W-1000, check that SYSTEM POWER Light is ON.

3.Check 3 amp circuit breaker, which is located above faceplate in W-1000 Power Center. Tripped circuit breaker is indicated by a white tab. Pushto reset.

4.If circuit breaker continues to trip, refer to a qualified Service Company.

5.At the W-1000, turn REMOTE CONTROLS Switch to "OFF" position.

If the equipment can now be operated, there may be a malfunction at the Spa-side Remote Control.

FILTER PUMP DOES NOT OPERATE:

1.At the CP-1000, push FILTER Equipment Button, and check that Status Light is ON.

2.At the W-1000, turn FILTER Equipment Service Switch to "ON" position.

3.If filter pump operates, there is a possible malfunction at the CP-1000.

4.If filter pump does not operate, pump may require servicing.

AUX 1 DOES NOT OPERATE:

1.At the CP-1000, push AUX 1 Equipment Button, and check that Status Light is ON. If AUX 1 activates a pool cleaner, there will be a 4 minute delay.

2.At the W-1000, turn AUX 1 Equipment Service Switch to "ON" position.

3.If equipment operates, there is a possible malfunction at the CP-1000.

4.If equipment does not operate, the equipment may require servicing.

5.If AUX 1 activates a pool cleaner valve, check that cable has not been unplugged from Valve Operator

HEATER DOES NOT OPERATE:

1.At the CP-1000, make sure that HEAT SOURCE Switch is in either "HEATER" or "S.PREFUposition, and that THERMOSTAT Dial is set correctly.

2.Check Temperature Display. Three dashes, or an unreasonably high temperature indicates that there is a malfunction at the Water Sensor.

3.Check that filter pump is running.

4.Check the filter pressure. If filter is clogged, the heater may not be getting sufficient water flow.

5.Inside the heater, check pilot light and heater controls. Heater must be turned on, and its own thermostat must be turned all the way up.

6.Heater may require servicing.

SOLAR DOES NOT OPERATE:

Note: Ambient air temperature must be approximately 5 degrees warmer than the water temperature before solar system is activated.

1.Check that filter pump is running.

2.At the CP-1000, make sure that HEAT SOURCE Switch is in either "SOLAR" or "S.PREFUposition, and that THERMOSTAT Dial is set correctly.

3.Check that cable has not been unplugged from Solar Valve Operator.

4.At the W-1000, turn SOLAR CONTROL Switch to "ON" position, and check to see if solar valve rotates. Remember to return switch to "AUTO" position at completion of test.

SPA DOES NOT HEAT UP TO 104" F:

1.Inside the heater, check that thermostat is turned all the way up.

2.High limit control on heater may need adjustiug. Refer to a qualified Service Company.

3.At the CP-1000, if HEATER ON Light turns OFF before spa attains the maximum temperature of 104" , the Controller may need a calibration adjustment. Refer to a qualified Service Company.

Page 16