• Set the aperture value in increments of 1/3 EV or 1/2 EV. Set the exposure steps in [1. EV Steps] in the [ACustom Setting 1] menu. (p.116)

The Shake Reduction function is automatically disabled when the exposure mode is set to pmode.

Use a sturdy tripod and the cable switch CS-205 (optional) or Remote Control F (optional) to prevent camera shake when using pmode. Connect the cable switch to the cable release terminal (p.17).

To operate the shutter release button of the remote control, set in [17. Remote Control in Bulb] in the [ACustom Setting 3] menu (p.86).

When the sensitivity is set to [AUTO] and the exposure mode is set to p mode, the sensitivity is the lowest sensitivity set in “Setting the Range of Automatic Sensitivity Correction” (p.90).

When the exposure mode is set to p, the upper sensitivity limit is ISO 1600.

There is no limit on exposure time for Bulb shooting. However, we recommend using the AC adapter kit K-AC50 (optional) when shooting with a long exposure setting as the battery is used while the shutter remains open. (p.47)

e-dial in p& Mmodes

You can set the functions of the front and rear e-dials in pand M modes. Set in [27. e-dial in B & X modes] in the [ACustom Setting 4] menu (p.86).

Settings

Front e-dial (R)

Rear e-dial (S)

1

– (Not Available)

c(Aperture)

 

 

 

2

c(Aperture)

– (Not Available)

 

 

 

3

Sensitivity

c(Aperture)

 

 

 

4

c(Aperture)

Sensitivity

 

 

 

111