308

10

Appendix

Problem

Cause

Remedy

 

The focus mode is

Set the focus mode lever to lor A.

 

set to \

(p.118)

The

 

Autofocus is not locked (focus lock) when

autofocus

 

the focus mode is set to k(A). The

does not

The focus mode is

camera will continue focusing on the subject

work

set to k

while the shutter release button is pressed

 

 

halfway. If there is a subject that you wish to

 

 

focus on, slide the focus mode lever to l

 

 

and use the focus lock. (p.124)

AE lock

AE lock is not

Set the exposure mode to any mode other

function

available when set

than B(Green), p(Bulb) or M(Flash X-

does not

to B, por Mmode.

sync Speed).

operate

 

 

 

 

Only C(Auto Flash Discharge) and D

 

 

(Auto Flash+Red-eye Reduction) are

The flash

 

available for the flash mode when the

The exposure mode

exposure mode is B(Green). The flash will

does not

is set to Bmode

not discharge when the subject is bright in

discharge

these modes. In the exposure modes other

 

 

 

than B, only the flash mode that

 

 

discharges every time the flash recharges is

 

 

available. Try different exposure modes.

The USB

 

 

connection

 

Set [USB Connection] in the [RSet-up 2]

with a

The USB connection

menu to [MSC]. (p.275)

computer

mode is set to [PTP]

Refer to the provided “Quick Guide” for

does not

details on connecting the camera to a

work

 

computer.

properly

 

 

 

The Shake

Set [Shake Reduction] in the [ARec. Mode

 

Reduction function

 

4] menu to k(On). (p.132)

 

is off

 

 

 

 

 

 

The Shake

If a lens for which focal length information

 

cannot be obtained is used, set [Focal

 

Reduction function

 

Length] in the [Input Focal Length] menu.

Shake

is not set properly

(p.135)

Reduction

 

 

Shutter speed is too

 

does not

 

work

low for the Shake

Turn off the Shake Reduction function and

 

Reduction function

 

to be effective when

use a tripod.

 

panning or shooting

 

 

night scenes, etc.

 

 

The subject is too

Move away from the subject, or turn off the

 

close

Shake Reduction function and use a tripod.