Press the [ENT] key to accept the Prism
Constant to -25 mm.
Pressing the [ENT] key returns the instrument
to mode A.
To set the Reflector sheet constant to 0select 0for Prism Constantin
Initial Setting 1.
To set the Prism constant to 0or - 30select 0or - 30for Prism
Constantin Initial Setting 1.
When the Reflector sheet Constanthas been set to 0in Initial Setting 1
and Prism Constanthas been set to 0or - 30", “”is displayed to the left
of 0or - 30on the correction menu screen.When “”is on the screen, the
Constant cannot be changed (by entering a numeric key).
Once set, the Reflector sheet Constant and Prism Constant remains on the
measurement screen as S 0or P 0.
The factory initial of Reflector sheet Constant and Prism Constant are 0.
Once set, each Constant remains in memory even after the power is turned
oft.
47
7 CORRECTION MODE
CORRECTION
1.
PRISM CONST
: -25mm
2.
SHEET CONST
0mm
3.TEMP 15°C
4.PRESS 1013hPa
5.ppm 0ppm
SELECT
MEAS TARGET 0 SET DISP MODE
MODE A 15°CS0
H. angle 20"30'92°
H. dst.
V. dst.
PENTAX R-300 (p20-52) 10/30/02 11:08 AM Page 47