8 INITIAL SETTING
8 INITIAL SETTING

8-1 Overview

For the R-300 series, you can select and save the desired setting for a variety of
prescribed instrument conditions, called Initial Setting.
The Initial Setting is saved in four modes, “Initial Setting 1”, “Initial Setting 2”,
“Initial Setting 4”, and “Initial Setting 5”, in which you can select and save the
instrument conditions described below.
The factory default for each of these conditions is marked by .
To change Initial Setting, follow the operating procedures for entering each Initial
Setting mode on Page 53 and the operating procedures for changing an Initial
Setting on Page 55.

8-2 Entering the Mode for Initial Setting 1

Press the [POWER] key while holding [F1]
key down to access the screen for Initial
Setting 1.
Press [F3] [g] or [F4] [h] to position the
cursor at the item of interest.

8-3 Entering the Mode for Initial Setting 2

Press the [POWER] key while holding [F2]
key down to access the screen for Initial
setting 2.
Select the item of interest in the same way as in the mode for Initial setting 1.
Pressing [F2] [ ] scrolls the screen down five items; pressing [F1] [ ] scrolls
it up five items.
SELECT
SET 1
1.ATM CORR : AUTO
2.
PRISM CONST
: 0mm
3.
SHEET CONST
: 0mm
4.
CRV/REF CORR
: 0.14
5.
COMP AXIS
: NIL
SELECT
SET 1
1.ATM CORR : AUTO
2.
PRISM CONST
: 0mm
3.
SHEET CONST
: 0mm
4.
CRV/REF CORR
: 0.14
5.
COMP AXIS
: NIL
SELECT
SET 2
1.
MEAS MIN DISP
: COARSE
2.SHOT COUNT : 1 TIME
3.SHOT INPUT : 01 TIMES
4.LD PLUM : ON
5.TILT DISP : ON