8-7 Initial Setting 1
1. Selection of Atmospheric Correction : [ATM CORR]
Select whether Atmospheric Correction is to be
performed by using the automatic measurement
correction function with a atmospheric sensor, by
entering the atmospheric temperature and pressure
measured with a thermometer and barometer, by
entering ppm value, or by fixing the ppm value to 0 (NIL)
not to perform Atmospheric Correction.
2. Selection of Prism Constant : [PRISM CONST]
Select whether the Prism Constant to be input is set to 0
mm, - 30mm or to an arbitrary value to be entered from
the keyboard.
3. Selection of Reflector sheet Constant : [SHEET CONST]
Select whether the target constant to be input is set to 0
mm, or to an arbitrary value to be entered from the
keyboard.
4. Selection for Refraction & Curvature Corrections :
[CRV/REF CORR]
Select whether the correction factor to be input for both
differences (Refraction, Curvature) is set to 0.14, 0.2, or
none (NIL). Selecting 3. NILresults in no correction of
both values.
5. Selection of Tilt Compensation : [COMP AXIS]
Select whether Tilt Compensation is to be single-axis
compensation, dual-axis compensation, or disabled
(NIL).
The factory default for each instrumet condition is
marked by .
56
8 INITIAL SETTING
1. AUTO
2. ATM INPUT
3. ppm INPUT
4. NIL
1. 0mm
2. INPUT
1. -30mm
2. 0mm
3. INPUT
1. 0.14
2. 0.2
3. NIL
1. 2 AXES
2. AXIS
3. NIL
1. 3 AXIS
2. 2 AXIS
3. 1 AXIS
4. NIL
PENTAX R-300 (p53-64) 10/30/02 11:13 AM Page 56