42
Example:“TRACK CONT”at second MEAS (Factory default setting)
Collimate the telescope at a Target
and press [F1] [MEAS] twice in succession
to start measuring the distance,
upon reception of a reflected light from the
target,the instrument beeps and displays
the _ mark to start the TRACK distance measurement.
If the instrument is in mode B,press [F5] [MODE] to switch to mode A and press [F1]
[MEAS ] twice.
Pressing [F1] [MEAS] twice after collimating the telescope at the Target starts
Continuous distance measurement at fast speed with the “MEAS”text blinking.
It remains blinking during the measurement.
If you press the [F1] [MEAS] again,Distance measurement is completed and the
“MEAS”text stops blinking.
Pressing [F4] [DISP] cycles through the sets of display items:“H.angle/H.dst./V.dst.”,
“H.angle/V.angle/S.dst.”,and “H.angle/V.angle/H.dst./S.dst./V.dst.”
Pressing the [ESC] or [F2] [TARGET] or [F5] [MODE] during fast distance measurement
stops it.
6.3 Quick mode
The Quick Mode is to shorten the measuring time using prism or reflector sheet.
The Quick Mode is effective to measure the distance up to 500M using prism or
reflector sheet.
After selecting Quick Mode from the Quick Mode
setting screen,the distance measurement
is done in Quick Mode.
If the quick mode is selected,
the distance measurement mark,
"<-<- ->->",instead of "((( )))", is displayed
H.angle
H.dst.
V.dst. CONT ((( )) )
MEAS TARGET 0 SET DISP MODE
MODE A 15°C S 0
92°30’ 20”
H.angle
H.dst.
V.dst. CONT
MEAS TARGET 0 SET DISP MODE
MODE A 15°C S 0
92°30’ 20”