8.7 Example of changing an initial setting content (selection of atmospheric correction)This section describes the operating procedures for selecting “1.ATM CORR”in Initial
Setting 1 as an example of changing an Initial Setting content.Use this example as a
reference when changing other items because it is also applicable to the operating
procedures for changing them.
Access the screen for Initial Setting 1 by taking
procedures “8.2 Entering the Mode
for Initial Setting 1”.
Press [F5] [SELECT] to open the screen for
selecting the atmospheric correction.
Press [F3] [ ] or [F4] [ ] to position the cursor
at the desired item,then press [ENT] key to select
that item.
Pressing the [ENT] key settles the change of
selected item.Pressing the [ESC] key invalidates
the change of selected item.
Pressing again the [ESC] key or [ENT] key quits the
initial setting screen and usual start screen appears.
8.8 Initial setting 11. Selection of Atmospheric Correction:[ATM CORR]
Select whether Atmospheric Correction is to be performed by
using the automatic measurement correction function with a
atmospheric sensor,by entering the atmospheric temperature
and pressure measured with a thermometer and barometer,
by entering ppm value,or by fixing the ppm value to 0 (NIL) not
to perform Atmospheric Correction.
SELECT
SET 1
1.ATM CORR : AUTO
2.PRISM CONST : 0mm
3.SHEET CONST : 0mm
4.CRV/REF CORR : 0.14
5.COMP AXIS : NIL
SELECT
SET 1
1.ATM CORR : 1.AUTO
2.PRISM CONST : 2.ATM INPUT
3.SHEET CONST : 3. ppm INPUT
4.CRV/REF CORR : 4. NIL
5.COMP AXIS : NIL
SELECT
SET 1
1.ATM CORR : 1.AUTO
2.PRISM CONST : 2.ATM INPUT
3.SHEET CONST : 3. ppm INPUT
4.CRV/REF CORR : 4. NIL
5.COMP AXIS : NIL
SELECT
SET 1
1.ATM CORR : ATM INPUT
2.PRISM CONST : 0mm
3.SHEET CONST : 0mm
4.CRV/REF CORR : 0.14
5.COMP AXIS : NIL
1. AUTO
2. ATM INPUT
3. ppm INPUT
4. NIL