69
[Note]
• The measurement range may vary by measurement conditions.
• Normal conditions:20km visibility with slight shimmer.
• Good conditions:40km visibility, overcast,no heat, no shimmer and moderate wind.
• Reflector sheet:PENTAX genuine reflector sheet (5cm x 5cm).
• Quick Mode,wich is effective only under Normal mode (1mm) setting,func tions with
Prism and Reflectorless Sheet.It is incorporated in all X series models and effective
up to 500m.
• When Quick Mode is on,the EDM accuracy using prism and reflector sheet is
±(3+2ppm x D)mm. When automatic correction is activated in Quick Mode,the EDM
accuracy is ±(3 +10ppm x D)mm.
• EDM Measuring time varies according to distance to be measured and conditions of
the environment.
• Reflectorless:
- The measurement range and accuracy of Reflectorless are based on the condition
that laser beam is emitted perpendicular to the white side of the Kodak Gray Card.
- The measurement range may be influenced by the shape of the target and its
environment.
- The measurement range at TRACK mode is over 5m.
• The operating time becomes shorter under the low temperature,due to the
temperature dependence of the battery performance.
• The points that can be recorded in one job file are maximum 2,000 measuring points
(XYZ).The user can make up to 50 job files.Job histor y can be managed thanks to date
clock recorded in each job file.
12. DATA COLLECTORThe instrument can communicate directly with a computer through the RS232C interface.
By use of a data collector you can automate data entry from the collection of survey data
to the transfer of the data to a computer.This is useful in saving time and protecting data
integrity.
About connection with data collector and the handling,please refer to an
“Instruction manual”of the data collector.
Connecting a data collector to a computer is different with every system.
Please contact your local dealer about them.