Adjustment

13.06.05 Thread-trimmer drive linkage

Requirement

1.On the PFAFF 1296 thread-catcher drive linkage 1 must have a length of 128 mm, less half of the needle gauge.

On the PFAFF 1295, thread catcher drive linkage 1 must have a length of 128 mm

2.When the threa trimmer is in its resting position there must be a clearance of about 1 mm between plunger 5 and lever 6.

2

1

2

6

 

5

4

1 mm

3

 

 

Fig. 11 - 22

● Turn thread-catcher drive linkage 1 (nuts 2) to adjust it according to Requirement 1. ● Re-position bracket 3 (screw 4) according to Requirement 2.

13 - 24