Adjustment

13.07 Parameter settings

(only on machines with Quick-EcoDrive and control unit P40ED)

● The selection of the user level and the alteration of parameters is described in the separate instruction manual for the drive unit.

13.07.01

Parameter list

 

 

 

 

 

 

 

 

 

 

 

 

 

Group

Parameter

 

Description

User lever

Setting range

Set value

 

 

 

 

 

 

 

 

 

1

105

 

Speed for start backtack

B, C

300 - 2000

600

 

 

 

 

 

 

 

 

 

 

110

 

Speed for end backtack

B, C

300 - 2000

800

 

 

 

 

 

 

 

 

 

6

607

 

Speed max.

B, C

300 - 6000

 

 

 

 

 

 

 

 

 

 

609

 

Cutting speed 1

B, C

60 - 300

180

 

 

 

 

 

 

 

 

 

7

700

 

Needle position 0

B, C

0 - 255

*

 

 

 

 

(needle reference position)

 

 

 

 

 

 

 

 

 

 

 

 

 

702

 

Needle position 1 (needle lowered)

B, C

0 - 255

80

 

 

 

 

 

 

 

 

 

 

703

 

Needle position 2 (take-up lever raised)

B, C

0 - 255

225

 

 

 

 

 

 

 

 

 

 

705

 

Needle position 5 (end cutting signal 1)

B, C

0 - 255

100

 

 

 

 

 

 

 

 

 

 

706

 

Needle position 5 (start cutting signal 2)

B, C

0 - 255

80

 

 

 

 

 

 

 

 

 

 

707

 

Needle position 9 (start thread tension

B, C

0 - 255

195

 

 

 

 

release/start thread catcher)

 

 

 

 

 

 

 

 

 

 

 

 

 

722

 

Acceleration ramp

B,C

1 - 60

45

 

 

 

 

 

 

 

 

 

 

723

 

Brake ramp

B,C

1 - 60

40

 

 

 

 

 

 

 

 

 

 

734

 

Tact output A2 (thread trimming)

B,C

001 - 009

0

 

 

 

 

 

 

 

 

 

 

760

 

Multiplier for the fixed value (200) for

A, B, C

0 - 250

5

 

 

 

 

stitch count

 

 

 

 

 

 

 

 

 

 

 

 

 

799

 

Selected machine class

C

1 - 4

2

 

 

 

 

 

 

 

 

See Chapter 3 Specifications

*Adjustment see Chapter 8.05 Basic position of the machine drive unit (in the machine instruction manual)