Adjustment
13.07 Parameter settings
(only on machines with Quick-EcoDrive and control unit P40ED)
● The selection of the user level and the alteration of parameters is described in the separate instruction manual for the drive unit.
13.07.01 | Parameter list |
|
|
|
| ||
|
|
|
|
|
|
|
|
| Group | Parameter |
| Description | User lever | Setting range | Set value |
|
|
|
|
|
|
|
|
| 1 | 105 |
| Speed for start backtack | B, C | 300 - 2000 | 600 |
|
|
|
|
|
|
|
|
|
| 110 |
| Speed for end backtack | B, C | 300 - 2000 | 800 |
|
|
|
|
|
|
|
|
| 6 | 607 |
| Speed max. | B, C | 300 - 6000 | ▲ |
|
|
|
|
|
|
|
|
|
| 609 |
| Cutting speed 1 | B, C | 60 - 300 | 180 |
|
|
|
|
|
|
|
|
| 7 | 700 |
| Needle position 0 | B, C | 0 - 255 | * |
|
|
|
| (needle reference position) |
|
|
|
|
|
|
|
|
|
|
|
|
| 702 |
| Needle position 1 (needle lowered) | B, C | 0 - 255 | 80 |
|
|
|
|
|
|
|
|
|
| 703 |
| Needle position 2 | B, C | 0 - 255 | 225 |
|
|
|
|
|
|
|
|
|
| 705 |
| Needle position 5 (end cutting signal 1) | B, C | 0 - 255 | 100 |
|
|
|
|
|
|
|
|
|
| 706 |
| Needle position 5 (start cutting signal 2) | B, C | 0 - 255 | 80 |
|
|
|
|
|
|
|
|
|
| 707 |
| Needle position 9 (start thread tension | B, C | 0 - 255 | 195 |
|
|
|
| release/start thread catcher) |
|
|
|
|
|
|
|
|
|
|
|
|
| 722 |
| Acceleration ramp | B,C | 1 - 60 | 45 |
|
|
|
|
|
|
|
|
|
| 723 |
| Brake ramp | B,C | 1 - 60 | 40 |
|
|
|
|
|
|
|
|
|
| 734 |
| Tact output A2 (thread trimming) | B,C | 001 - 009 | 0 |
|
|
|
|
|
|
|
|
|
| 760 |
| Multiplier for the fixed value (200) for | A, B, C | 0 - 250 | 5 |
|
|
|
| stitch count |
|
|
|
|
|
|
|
|
|
|
|
|
| 799 |
| Selected machine class | C | 1 - 4 | 2 |
|
|
|
|
|
|
|
|
▲See Chapter 3 Specifications
*Adjustment see Chapter 8.05 Basic position of the machine drive unit (in the machine instruction manual)
13 - 33