Adjustment
13.06.13 | Release rod |
Requirement
1.When the lifting presser is resting on the needle plate, pin 3 must rest at the lower end of the elongated hole in
2.The tension discs must not be moved apart in this position.
2
1
3
1
Fig. 11 - 30
●
13 - 32