Technical data

Signallevel on control socket

Connection

 

Signallevel

 

Note

 

 

 

 

Pin 1

HIGH: 5V

min. 0,5 sec.

Input active with LOW

ALARM IN

LOW: GND

 

 

signal level

Alarm input

 

 

 

 

 

 

 

 

Pin 2

HIGH: 5V - 12V

min. 0,5 sec.

Input active with LOW

SERIAL IN

LOW: GND

 

 

signal level

Starting the recording

 

 

 

 

on a second video

 

 

 

 

recording

 

 

 

 

 

 

 

 

Pin 3

HIGH: 5V

min. 0,5 sec.

Input active with LOW

RESET/REC OUT

LOW: GND

 

 

signal level

Alarmreset

 

 

 

Output active with HIGH

 

 

 

 

signal level

 

 

 

 

 

Pin 4

 

 

 

Mass

GND

 

 

 

 

 

 

 

 

Pin 5

HIGH: 12V

Setting the menu in ALARM

Output active with HIGH

ALARM OUT

Iout = max. 50mA

SETTINGS

signal level

Alarm output

Short circuit protected

 

 

 

 

 

 

 

 

Pin 6

HIGH: 12V

10 sec.

 

Output active with LOW

SERIAL OUT

Iout = max. 50mA

 

 

signal level

Output for starting a

Short circuit protected

 

 

 

second video recorder

 

 

 

 

 

 

 

 

Pin 7

HIGH: 5V

4 frames after the recorded

Output active with LOW

CAMERA SW OUT

LOW: max. 0,8V

frame

 

signal level

Camera switching pulse

Internal pullup 5kOhm

 

 

 

 

 

 

 

 

Pin 8

HIGH: min. 11V

15 Minutes be-

EJECT or

Output active with LOW

TAPE END OUT

Iout = max. 50mA

fore end of tape

REWIND

signal level

Tape end warning

Short circuit protected

 

 

 

 

 

 

 

Pin 9

HIGH: 5V - 12V

at least 0,5 sec.

Input active with LOW

RECORD CHECK

LOW: GND

 

 

signal level

 

 

 

 

 

17

Page 17
Image 17
Philips TL960A5T operating instructions Technical data, Connection Signallevel