English

the filtered water flow will be extremely low or the water purifier

will get damaged.

Installation A-type adapter

-For taps with a round spout with a diameter of 16mm, 17.5mm or 19mm (Fig. 2).

1Remove the attachment nut and the adapter from the water purifier housing (Fig. 3).

2Pass the attachment nut over the tap spout (Fig. 4).

3Place the matching adapter (A-type) over the tip of the spout.The 16mm adapter is packed with the water purifier. Replace it with the 17.5mm adapter or 19mm adapter to fit the diameter of your tap (Fig. 5).

4Screw the attachment nut firmly onto the water purifier housing (Fig. 6).

Installation B-type adapter

-For taps with an aerator (threaded on the outside) (Fig. 7).

1Remove the attachment nut and the adapter from the water purifier (Fig. 8).

2Remove the aerator cap from the tap and pass the attachment nut over the spout.Take out the original adapter and screw the matching adapter (B-type) onto the tap (Fig. 9).

3Tighten the adapter further with a coin (Fig. 10).

4Firmly screw the attachment nut onto the water purifier housing (Fig. 11).

Installation C-type adapter

-For taps with an aerator (threaded on the inside) (Fig. 12).

1Remove the attachment nut and the adapter from the water purifier housing (Fig. 13).