Photogenic Professional Lighting PM800 Operational Parameters, Flashing Rate, Power Level, Time

Models: PM400 PM800 PM400R PM800R

1 20
Download 20 pages 63.47 Kb
Page 13
Image 13

OPERATIONAL PARAMETERS

Voltage Smart PhotoMaster PM800, PM800R

Flashing Rate:

The unit recharges quickly, as indicated by the READY light on the control panel. A quick series of flashes can be obtained within the limits of the recharge time. Continuous rapid flashing, however, can overheat and damage the flashtube and internal parts. The maximum recommended rate of flashing would depend upon the power level being used and the amount of operation time. Use the following chart to serve as a guide for the maximum rate to use in your situation.

Power Level

Operating

Sec. Between

Number of

 

Time

Flashes.

Flashes

Full

Continuous

15

Continuous

 

13 Minutes

10

81

 

2.7 Minutes

5

32

1/2

Continuous

8

Continuous

 

6.8 Minutes

4

100

 

2 Minutes

2

58

1/4

Continuous

3.3

Continuous

Exposure Information:

The following charts give the BCPS output for various umbrellas and reflectors. Coverage angle is given in degrees.

Umbrella

 

 

 

32 inch

 

 

45 inch

 

60 inch

Coverage

 

 

120 degree

 

 

120 degree

120 degree

 

 

 

 

 

 

 

 

 

 

 

 

 

Full Power

 

 

8800

 

 

8933

 

 

8933

½

 

 

4400

 

 

4466

 

 

4466

¼

 

 

2200

 

 

2233

 

 

2233

1/8

 

 

1100

 

 

1117

 

 

1117

1/16

 

 

550

 

 

558

 

 

558

1/32

 

 

275

 

 

279

 

 

279

 

 

 

 

 

 

 

 

 

 

 

 

 

Reflector

 

 

 

 

 

 

 

 

 

 

 

 

Diameter

None

 

7 ½”

 

14”

 

16”

 

20”

 

24”

Coverage

360°

 

35°

40°

 

60°

 

65°

 

145°

 

 

 

 

 

 

 

 

 

 

 

Full Power

3733

 

40000

28000

 

37333

 

26133

 

6720

½

1866

 

20000

14000

 

18666

 

13066

 

3360

¼

933

 

10000

7000

 

9333

 

6533

 

1680

1/8

467

 

5000

3500

 

4667

 

3267

 

840

1/16

233

 

2500

1750

 

2333

 

1633

 

420

1/32

117

 

1250

875

 

1167

 

817

 

210

GN@ASA100/10’

128

 

412

344

 

396

 

332

 

168

13

Page 13
Image 13
Photogenic Professional Lighting Operational Parameters, Voltage Smart PhotoMaster PM800, PM800R, Flashing Rate, Time