ADVANCED POWERLIGHT FEATURES.
Voltage Smart PhotoMaster PM400, PM400R, PM800 & PM800R
Automatic Discharge
Each time the AC line power is disconnected or switched off, the unit will automatically
Unit Number Assignment
This feature allows the user to assign a UNIT NUMBER (1 to 9) to each PhotoMaster in the studio. The UNIT NUMBER is necessary when INFRARED remote control is used with the PM400R or PM800R models (see accessories.)
To assign a UNIT NUMBER, the startup sequence will need to be interrupted. Turn PhotoMaster AC power OFF. With the unit OFF press and hold the ½ stop “UP” button then turn the power switch to ON, continue holding the ½ stop button until the display reads “ir” then release the button. The Digital display should read “ir” when you press and release the ½ UP button again, and the display will then read “Un - 1”, or some number 1 to 9. To change the UNIT number, press and release the 1/10 UP/DOWN arrow buttons until the desired number is displayed. To save and close the assignment feature and save the UNIT number, press and release the 1/2 UP arrow button again. This allows the startup sequence to finish and save the new settings. Each “R” unit’s default unit number is set at “Un - 1”. You must re- set the unit number with the 1/10 adjustment buttons, or the default “Un 1” will automatically be assigned.
Wireless Setup.
The “R” units are