Photogenic Professional Lighting PM800R Modeling Lights, Test Function, Diagnostic Display Codes

Models: PM400 PM800 PM400R PM800R

1 20
Download 20 pages 63.47 Kb
Page 8
Image 8

Modeling Lights:

The modeling lights have three symmetrical modes of operation (NOT independent):

1.MANUAL adjusts the modeling lamp intensity using the 1/2 or 1/10 f-stops UP/DOWN arrow buttons. Press the manual ADJUST button (F) to turn the MODEL yellow LED (B) on. Pressing the manual ADJUST button (F) a second time will change the mode to flash adjustment and is indicated by the illuminated red Flash LED (A).

2.TRACK mode (Proportional modeling) causes the modeling lamp intensity to track the FLASH setting. The modeling lamp may be re-set to full intensity at any FLASH value, by simply pressing the TRACK/SET button (G) a second time, with the FLASH already set to desired watt-seconds. This setting is retained when the user returns from another mode.

3.FULL ON/OFF is exactly what it says. Press the FULL ON/OFF button (C) to turn the modeling lamp OFF (LED off) or ON (LED on).

Note: All current mode settings are retained, even after the power is turned off.

4.Each light head modeling lamp can also be turned on/off with rear switch on the respective light head.

Test Function:

The TEST Flash button is pressed to fire the flashtube for test purposes, to re-set after a misfire or to dump stored power when moving to a lower watt second level.

Ratio Light Head Flash Power:

The two left light heads (looking at the power supply front) can have a 3:1 flash power ratio to the two right light heads. There are four flash capacitors, of equal value, inside the power supply. All four light heads share the total flash power setting. The RATIO function simply connects the two left light heads to three flash capacitors and the two right light heads to one flash capacitor. [Note that if all four light heads are used, without ratio, each would deliver 1/4 of the flash power setting. If all four light heads are used, with ratio, the two left light heads would each deliver 3/8 of the flash setting, and the two right light heads would each deliver 1/8 of the flash setting (3:1 ratio). If using three heads (two left and one right), the two left heads would each deliver 3/8 of setting and the right head would deliver 1/4 of the setting. ] The RATIO feature can be turned ON (LED on) or OFF (LED off) with the RATIO/Auto Bracket button.

Diagnostic Display Codes:

In addition to internal thermal protection, the microcomputer software monitors the AC line power and flash power consumption to prevent catastrophic damage to your new PhotoMaster units. The following error codes may be displayed:

“Er-0” message means that an AC line power frequency problem has occurred. This could be internal or in the power cable or outlet at the location. Try turning the main power off, wait for 5 seconds and turn power back on.

“Er-1” message means that an AC line power voltage problem has occurred. This could be internal or can happen with voltage spikes and voltage fall-off in the location AC line power. Try turning the main power off, wait for 5 seconds and turn power back on.

8

Page 8
Image 8
Photogenic Professional Lighting PM800R, PM400R manual Modeling Lights, Test Function, Ratio Light Head Flash Power