To set up the lighting system, first mount and secure all light heads to suitable stands. The stand adapter allows the light head to be mounted on a stand with a 3/8” to 5/8” post. Be sure to use a stand that is stable and will not tip easily.
The light heads are shipped with the modeling lamp and flashtube not installed. While installing the modeling lamp and flashtube (with glove or clean cloth to protect the hand) be certain they are properly inserted and tight to avoid arcing and failure of the socket contacts during operation. Do not touch the glass tubes with bare hands, as normal body oils will shorten the bulb’s life. Always use a clean cloth or wear gloves to protect your hand from glass breakage and heat.
The 7 ½ inch reflector is attached to the PA8 by the
Squeeze levers to mount reflector in locked position.
Punch out hole for | Professional |
umbrella rod. | flashtube. |
With power supply’s power switch OFF, attach the line cord to the power- input connector, located on the back of the PhotoMaster, and connect it to a grounded wall outlet. Turn the power switch ON. The READY light will light when the unit has charged to the power level set by the FLASH power control.
4