![OPERATIONAL PARAMETERS](/images/new-backgrounds/144827/14482721x1.webp)
OPERATIONAL PARAMETERS
Voltage Smart PhotoMaster PM400R & PM400R
Flashing Rate:
The unit recharges quickly, as indicated by the READY light on the control panel. A quick series of flashes can be obtained within the limits of the recharge time. Continuous rapid flashing, however, can overheat and damage the flashtube and internal parts. The maximum recommended rate of flashing would depend upon the power level being used and the amount of operation time. Use the following chart to serve as a guide for the maximum rate to use in your situation.
Power Level | Operating | Sec. Between | Number of |
| Time | Flashes. | Flashes |
Full | Continuous | 8.3 | Continuous |
| 6.8 Minutes | 4 | 100 |
| 2 Minutes | 4 | 60 |
1/2 | Continuous | 3.3 | Continuous |
| 6.8 Minutes | 2 | 200 |
| 2 Minutes | 1 | 116 |
1/4 | Continuous | 2 | Continuous |
Exposure Information:
The following charts give the BCPS output for various umbrellas and reflectors. Coverage angle is given in degrees.
Umbrella | 32 inch | 45 inch | 60 inch |
Coverage | 120 degree | 120 degree | 120 degree |
|
|
|
|
Full Power | 4400 | 4466 | 4466 |
½ | 2200 | 2233 | 2233 |
¼ | 1100 | 1117 | 1117 |
1/8 | 550 | 558 | 558 |
1/16 | 275 | 279 | 279 |
1/32 | 137 | 140 | 140 |
Reflector |
|
|
|
Diameter | None | 7 ½” | 14” |
Coverage | 360° | 35° | 40° |
|
|
|
|
Full Power | 1866 | 20000 | 14000 |
½ | 933 | 10000 | 7000 |
¼ | 467 | 5000 | 3500 |
1/8 | 233 | 2500 | 1750 |
1/16 | 117 | 1250 | 875 |
1/32 | 58 | 625 | 438 |
GN@ASA100/10’ | 88 | 292 | 244 |
16” 60°
18666
9333
4667
2333
1167
583
280
20” | 24” |
65° | 145° |
|
|
13066 | 3360 |
6533 | 1680 |
3267 | 840 |
1633 | 420 |
817210
408105
236120
11