SPECIFICATIONS
7 GeneralSystem .................................................................. | 100 disc changer | |
Power requirements ..................... | AC 100V/120V/230V (switchable) | |
|
| 50/60 Hz |
Current drain .................................................................... | 1.6A(100V) | |
|
| 1.4A(120V) |
|
| 1.0A(230V) |
Weight (with disc magazine, without discs) ...... | 28.1 kg (61 lb 15 oz) | |
Dimensions ................................... | 263 (W) x 484 (H) x 588 (D) mm | |
| ||
Operating temperature ........................................... | +5°C ~ +35°C*1 | |
|
| +41°F ~ +95°F*1 |
Operating humidity .......................... | 5% – 85% (no condensation)*1 | |
Storage temperature .............................................. | ||
|
|
Disc storage (12
Removable disc magazines
.................... 2 magazines which hold 50 discs each can be stored.
7 Accessories |
|
Door key (for front door locking) ................................................... | 2 |
Power cord .................................................................................... | 2 |
Operating Instructions .................................................................... | 1 |
NOTE:
÷Specifications and design are subject to possible modifications without notice, due to improvements.
*1
Because the allowed operating temperature and the allowed operating humidity are limited by the drive that is installed, be sure to use the drive under the conditions stipulated in the operating instructions for the drive.
Notes:÷For safety, this unit has been designed so that the door cannot be opened while the
÷Since the disc rotates at a high speed in the
In order to ensure safe and proper functioning of this unit, we recommend regular maintenance. Extended service life can be expected if maintained properly.
+1
± |
|
|
| ¡ |
1) Pin layout of SCSI connectors |
|
| ||
|
|
|
|
|
Signal name | Pin No. |
| Signal name | |
|
|
|
|
|
GROUND | 1 |
| 26 | |
GROUND | 2 |
| 27 | |
GROUND | 3 |
| 28 | |
GROUND | 4 |
| 29 | |
GROUND | 5 |
| 30 | |
GROUND | 6 |
| 31 | |
GROUND | 7 |
| 32 | |
GROUND | 8 |
| 33 | |
GROUND | 9 |
| 34 | |
GROUND | 10 |
| 35 | GROUND |
GROUND | 11 |
| 36 | GROUND |
GROUND | 12 |
| 37 | GROUND |
NC | 13 |
| 38 | TERMPWR |
GROUND | 14 |
| 39 | GROUND |
GROUND | 15 |
| 40 | GROUND |
GROUND | 16 |
| 41 | |
GROUND | 17 |
| 42 | GROUND |
GROUND | 18 |
| 43 | |
GROUND | 19 |
| 44 | |
GROUND | 20 |
| 45 | |
GROUND | 21 |
| 46 | |
GROUND | 22 |
| 47 | |
GROUND | 23 |
| 48 | |
GROUND | 24 |
| 49 | |
GROUND | 25 |
| 50 | |
|
|
|
|
|
Notes:
÷Pin No. 13 is not grounded.
÷The connectors are of the shielded type.
÷For details on the control commands, refer to the separate specifications manual.
2) Electrical specifications of SCSIOutput | The signals driven by SCSI equipment present |
characteristics | the following output characteristics. |
| True (LOW): VOL = 0.0 to 0.5 V DC |
| IOL = 48 mA (0.5 V DC) max. |
| False (HIGH): VOH = 2.5 to 5.25 V DC |
|
|
Input | The signals driven by SCSI equipment present |
characteristics | the following input characteristics. |
| True (LOW): VOL = 0.0 to 0.8 V DC |
| IOL = |
| False (HIGH): VOH = 2.0 to 5.25 V DC |
|
|
Notes:
÷Terminate it at both ends of the SCSI bus.
÷The SCSI interface is
÷Use an
Published by Pioneer Corporation.
Copyright © 1999 Pioneer Corporation.
All rights reserved.
15