SPECIFICATIONS

7 General

System ..................................................................

100 disc changer

Power requirements .....................

AC 100V/120V/230V (switchable)

 

 

50/60 Hz

Current drain ....................................................................

1.6A(100V)

 

 

1.4A(120V)

 

 

1.0A(230V)

Weight (with disc magazine, without discs) ......

28.1 kg (61 lb 15 oz)

Dimensions ...................................

263 (W) x 484 (H) x 588 (D) mm

 

10-11/32 (W) x 19-1/16 (H) x 23-1/8 (D) in

Operating temperature ...........................................

+5°C ~ +35°C*1

 

 

+41°F ~ +95°F*1

Operating humidity ..........................

5% – 85% (no condensation)*1

Storage temperature ..............................................

–40°C ~ +60°C

 

 

–40°F ~ +140°F

7Functions

Disc storage (12 cm/5-inch discs) ..................................... 100 discs

Removable disc magazines

.................... 2 magazines which hold 50 discs each can be stored.

7 Accessories

 

Door key (for front door locking) ...................................................

2

Power cord ....................................................................................

2

Operating Instructions ....................................................................

1

NOTE:

÷Specifications and design are subject to possible modifications without notice, due to improvements.

*1

Because the allowed operating temperature and the allowed operating humidity are limited by the drive that is installed, be sure to use the drive under the conditions stipulated in the operating instructions for the drive.

Notes:

÷For safety, this unit has been designed so that the door cannot be opened while the built-in reader is operating.

÷Since the disc rotates at a high speed in the built-in reader, vibrations or noise may be generated as a result. Note that this is not a malfunction and that it will not exert adverse effects on the performance of the unit.

Maintenance

In order to ensure safe and proper functioning of this unit, we recommend regular maintenance. Extended service life can be expected if maintained properly.

SCSI connector specifications

+1

±

 

 

 

¡

1) Pin layout of SCSI connectors

 

 

 

 

 

 

 

Signal name

Pin No.

 

Signal name

 

 

 

 

 

GROUND

1

 

26

-DB(0)

GROUND

2

 

27

-DB(1)

GROUND

3

 

28

-DB(2)

GROUND

4

 

29

-DB(3)

GROUND

5

 

30

-DB(4)

GROUND

6

 

31

-DB(5)

GROUND

7

 

32

-DB(6)

GROUND

8

 

33

-DB(7)

GROUND

9

 

34

-DB(P)

GROUND

10

 

35

GROUND

GROUND

11

 

36

GROUND

GROUND

12

 

37

GROUND

NC

13

 

38

TERMPWR

GROUND

14

 

39

GROUND

GROUND

15

 

40

GROUND

GROUND

16

 

41

-ATN

GROUND

17

 

42

GROUND

GROUND

18

 

43

-BSY

GROUND

19

 

44

-ACK

GROUND

20

 

45

-RST

GROUND

21

 

46

-MSG

GROUND

22

 

47

-SEL

GROUND

23

 

48

-C/D

GROUND

24

 

49

-REQ

GROUND

25

 

50

-I/O

 

 

 

 

 

Notes:

÷Pin No. 13 is not grounded.

÷The connectors are of the shielded type.

÷For details on the control commands, refer to the separate specifications manual.

2) Electrical specifications of SCSI

Output

The signals driven by SCSI equipment present

characteristics

the following output characteristics.

 

True (LOW): VOL = 0.0 to 0.5 V DC

 

IOL = 48 mA (0.5 V DC) max.

 

False (HIGH): VOH = 2.5 to 5.25 V DC

 

 

Input

The signals driven by SCSI equipment present

characteristics

the following input characteristics.

 

True (LOW): VOL = 0.0 to 0.8 V DC

 

IOL = -0.4 mA to 0.0 mA (0.5 V DC)

 

False (HIGH): VOH = 2.0 to 5.25 V DC

 

 

Notes:

÷Terminate it at both ends of the SCSI bus.

÷The SCSI interface is single-end type.

÷Use an SCSI-use high impedance cable (characteristic impedance: 100 ±10) with a maximum length of 6 m (total length including the wiring inside the unit).

Published by Pioneer Corporation.

Copyright © 1999 Pioneer Corporation.

All rights reserved.

15

<DRC1129> En