09Advanced Setup Menu

SERIAL PORT

Set the RS-232C interface to use with a 15-pin connector or 9-pin connector. Only a single

type of connector may be used at a time. Use / (cursor left/right) buttons to alternate between 15 Pin and 9 pin (Default setting is 15 Pin).

15 Pin: When connecting to a PC using a Pioneer or other brand 15-pin to 9-pin cable.

9 Pin: When connecting to a PC using a commercial 9-pin cross-cable.

BAUD RATE

Sets the Baud rate for the RS-232C

interface.

Use / (cursor left/right) buttons to alternate between 19200 bps and 9600 bps (Default setting is 19200 bps).

EXTEND TERMINAL

Use the Extend Terminal to select a switch-

key setting.

Use / (cursor left/right) buttons to alternate between Standard and User (Default setting is Standard).

Standard: The unit responds according to established standard setting (see pages 68 – 70).

User: The user selects how the external option key responds. Press ENTER to activate this option (see page 46).

SYNC OUT (DURING SQ)

Use SYNC OUT to determine if a video signal

is sent when the player is not playing video. Use / (cursor left/right) buttons to alternate between ON and OFF (Default setting is OFF).

OFF: Video is output constantly; the sync signal is ON.

ON: Video is not output except during playback and when displaying menu screens (sync signal is off).

Power On Start

Sets playback mode when power is turned on.

1Press and hold HOME MENU for one second.

The screen displays the ADV. SETUP menu.

2Use the  (cursor down) button to select POWER ON START.

3Use the / (cursor left/right) buttons to select a mode other than OFF, then press ENTER.

When OFF is selected, Power On Start function is disabled.

4Use the / (cursor up/down) buttons to select 1, 2, or 3, then press ENTER.

If the power is interruputed while saving the ADV. SETUP menu settings during video playback and the disc is still spinning, the settings are not recoreded. When disconnecting the power cord, always turn off the main power switch first (the power indicator is not lit) or use the remote control to set the unit to Standby mode (the power indicator changes to orange).

42