15. GREEN Gain Data
Function
The external control equipment changes the GREEN Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag 01H
DATA01 : GREEN Gain Flag 02H
DATA02 : GREEN Low D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
DATA03: GREEN High D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: GREEN Gain Flag 02H