PDP-614MX External Control Manual
46
58.BLACK LEVEL SELECT
Function
External control apparatus sets up the black level (digital signal level) of a plasma monitor.
Transmission Data

DFH 80H 60H 8FH 01H DATA00 CKS

DATA00 01H : LOW
02H : HIGH
ACK

7FH 60H 80H 8FH 01H DATA00 CKS

DATA00 01H : LOW

02H : HIGH

59.OSM CONTRAST SELECT
Function
External control apparatus selects the OSM contrast function of a plasma monitor.
Transmission Data

DFH 80H 60H 37H 01H DATA00 CKS

DATA00 01H : NORMAL
02H : LOW
ACK

7FH 60H 80H 37H 01H DATA00 CKS

DATA00 01H : NORMAL
02H : LOW
.60OSM Select
Function
The external control equipment switches on or off the on-screen menu (OSM) of the plasma monitor.
Transmission Data
DFH 80H 60H 58H 01H DATA00 CKS

DATA00: 01H: On-Screen menu On

02H: On-Screen menu Off
ACK
7FH 60H 80H 58H 01H DATA00 CKS

DATA00: 01H: On-Screen menu On

02H: On-Screen menu Off
*Operation is as described in the table below.
On-Screen Menu (OSM)
Display of items and adjustments
on the menu
Volume display, input display, and
screen size display
Operation
When screen
menu is ON
When screen
menu is OFF
When screen
menu is ON
When screen
menu is OFF