57
72. ORBITER SET
Function
A picture shift function is set up.
Transmission Data

DFH 80H 60H 1EH 04H DATA00 to DATA03 CKS

DATA00: Mode 00H : OFF
01H : Auto 1
02H : Auto 2
03H : Manual
DATA01: The horizontal amount of movements
1 dot : 01H
to : -
20 dot : 14H
DATA02: The vertical amount of movements
One line : 01H
to : -
20 line : 14H
DATA03: Interval of operation 1 - 5 minutes : 01H - 05H
ACK

7FH 60H 80H 1EH 01H DATA00 CKS

DATA00: Mode 00H : OFF
01H : Auto 1
02H : Auto 2
03H : Manual
* DATA01-03
Auto1,2 setting : 01H fixed
Manual setting : Please set DATA 01-03.
73. OSM ANGLE
Function
The vertical display of OSM and a horizontal display are chosen.
Transmission Data
DFH 80H 60H 60H 01H DATA00 CKS
DATA00 01H : Horizontal display
02H : Vertical display
ACK

7FH 60H 80H 60H 01H DATA00 CKS

DATA00 01H : Horizontal display
02H : Vertical display
74. PICTURE Size
Function
Screen mode selection.