PDP-614MX External Control Manual
22
23. H.POSITION Gain Data
Function
The external control equipment changes the H. POSITION gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag 03H
DATA01 : H.POSITION Gain Flag 02H
DATA02 : H.POSITION Gain 80H : -128
:
FFH : -01
00H : 0
01H : +01
:
7FH : +127
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 03H
DATA01: H.POSITION Gain Flag 02H
24. V.SIZE Gain Data
Function
The external control equipment changes the V.SIZE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag 03H
DATA01 : V.SIZE Gain Flag 07H
DATA02 : V.SIZE Gain 00H : 0
:
40H : +64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 03H
DATA01: V.SIZE Gain Flag 07H