25. H.SIZE Gain Data
Function
The external control equipment changes the H.SIZE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag 03H
DATA01 : H.SIZE Gain Flag 08H
DATA02 : H.SIZE Gain 00H : 0
:
40H : +64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 03H
DATA01: H.SIZE Gain Flag 08H
26. AUTO PICTURE Select
Function
The external control equipment switches on or off the AUTO PICTURE of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag 03H
DATA01 : AUTO PICTURE Select Flag 09H
DATA02 00H : ON
01H : OFF
ACK
7FH 60H 80H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag 03H
DATA01 : AUTO PICTURE Select Flag 09H
DATA02 00H : ON
01H : OFF