PDP-614MX External Control Manual
58
Transmission Data
DFH 80H 60H 2AH 01H DATA00 CKS
DATA00 01H : ON
02H : OFF
ACK
7FH 60H 80H 2AH 01H DATA00 CKS
DATA00 01H : ON
02H : OFF
75. OPTION Select
Function
Power-on mode, a control lock, and IR remote are set up.
Transmission Data
DFH 80H 60H 63H 04H DATA00 to DATA03 CKS
DATA00 : Power ON mode 00H : LAST
01H : Video1
02H : Video2
03H : Video3
05H : COMPNT1
06H: COMPNT2
07H : PC1DSUB
08H : PC2-BNC
0CH : PC3-DVI
DATA01 : Control Lock 00H : OFF
01H : ON
DATA02 : IR remote 00H : OFF
01H : ON
DATA03 : Loop Out 00H : OFF
01H : ON
ACK
7FH 60H 80H 63H 00H CKS
76. REPEAT Timer
Function
External control apparatus sets up the repeat timer of a plasma monitor.
Transmission Data
DFH 80H 60H 64H 07H DATA00 to DATA06 CKS
DATA00 00H :REPEAT Timer OFF
01H :REPEAT Timer ON
DATA01 PROGRAM 1
01H :DIVIDER 1
02H :DIVIDER 4
03H :DIVIDER 9
DATA02 SOURCE 01H :Video1
02H :Video2
03H :Video3
05H : COMPNT1
06H : COMPNT2
07H : PC1DSUB
08H : PC2-BNC