PDP-614MX External Control Manual
48
62. TIMER SWITCH
Function
The external control equipment sets the timer reservation of the plasma monitor.
Transmission Data
DFH 80H 60H 02H 01H DATA00 CKS
DATA00: 00H : Reservation OFF
01H : Reservation ON
ACK
7FH 60H 80H 02H 01H DATA00 CKS
DATA00: 00H : Reservation OFF
01H : Reservation ON
63. TIMER PROGRAM SETTING
Function
External control apparatus sets up the timer program of a plasma monitor.
Transmission Data
DFH 80H 60H 30H 08H DATA00 to DATA07 CKS
DATA00 PROGRAM No
01H~07H :No1~No7
DATA01 DATE
01H~07H : Sunday - Saturday
08H : Every day
09H~0FH : Every week Sunday - every week Saturday
FFH : - (with No Setup)
DATA02 ON time (HOUR)
00H~09H :00~09
10H~19H :10~19
20H~23H :20~23
FFH : - (with No Setup)
DATA03 ON time (MIN)
00H~09H :00~09
10H~19H :10~19
20H~29H :20~29
30H~39H :30~39
40H~49H :40~49
50H~59H :50~59
FFH : - (with No Setup)
DATA04 OFF time (HOUR)
00H~09H :00~09
10H~19H :10~19
20H~23H :20~23
FFH : - (with No Setup)
DATA05 OFF time(MIN)
00H~09H :00~09
10H~19H :10~19
20H~29H :20~29
30H~39H :30~39
40H~49H :40~49
50H~59H :50~59
FFH : - (with No Setup)