PDP-614MX External Control Manual
70. POWER DELAY ON(at 4 or 9 multiscreen)
Function
External control apparatus attaches a time lag to two or more plasma monitors, and turns on a power supply.
Transmission Data
DFH 80H 60H F2H 01H DATA00 CKS
DATA00: 00H-FFH: Delay time (second)
*:Turn on the AUTO ID and set the DIVIDER(at 4 or 9), before this operation
*: This command is premised on two or more plasma monitor system composition being multi-systems. In command issue of
master1 OSD operation, the value of DATA00 is 01H (1 second). This command does not have ACK for one-way traffic.
*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.
71. POWER DELAY ON (at 16 or 25 multi screens)
Function
External control apparatus attaches a time lag to 10 or more plasma monitors, and turns on a power supply.
Transmission Data
DFH 80H 60H F6H 01H DATA00 CKS
DATA00: 01H mode1
02H mode2
ACK
7FH 60H 80H F6H 01H DATA00 CKS
DATA00: 01H mode1
02H mode2
NOTE: When multi mode is 16 or 25, this function is available.