a. This test requires a DC millivolt meter set to a scale of O-l(XK)mv.
b. Locate the thermopile wires coming from the thermostat!High Limit box going to the gas
shut off valve. The wire insulation size decreases near the gas valve connections.
Connect the negative (-) test probe to pilot bracket.
Connect the positive (+) test probe to one of the High Limit terminal
Remove the pilot flame adjustment cover.
PRESSURE REGULATOR
(UNDER CAP SCREW)
Co

d.

e.
PILOT ADJUSTER LOCATION
(UNDER CAP SCREW)
g. Rotate the screw in the direction to achieve a reading of 400 rlO mv for thermopiles.
h. Replace the pilot flame adjusting screw cover.
LOCATION
NonCE