N500 User Guide
Fitting the PROM 1. Turn power OFF at the wall outlet.2. Remove the platform by lifting straight upwards.
3. Slide the old PROM out of its location slot. Resistance will be felt. Put this PROM to one side for now.
4. Slide the new PROM into the empty slot ensuring the opening in the PROM handle is in the top right hand corner. Resistance will be felt once the PROM has made contact with its connector.
5.Push the PROM into its slot until it snaps into place and is firmly seated into its connector. MODERATE pressure may be required.
6.Refit the platform and turn the scale ON from the wall outlet.
If, after fitting the PROM and switching ON, the scale display will not light or an error is displayed, check that the PROM has been fitted fully into its slot as described above. If the scale still does not function correctly, call Pitney Bowes for assistance.
7.Make sure the scale is level after fitting the PROM. If necessary, re- level the scale by turning its feet until the bubble in the level indicator is centred.
8.Return the old PROM to Pitney Bowes following the instructions received with the new PROM.
27