Precautions
Interference During Exercise
Electromagnetic Interference and Exercise Equipment
Disturbance may occur near
Exercise equipment with electronic or electrical components such as LED displays, motors and electrical brakes may cause interfering stray signals. To solve these problems, try the following:
1.Remove the transmitter from your chest and use the exercise equipment as you would normally.
2.Move the Training System around until you find an area in which it displays no stray reading or does not flash the heart symbol. Interference is often strongest directly in front of the display panel of the equipment, while the left or right side of the display is relatively free of disturbance.
3.Put the transmitter back on your chest and keep the Training System in this
If the Training System still does not work with the exercise equipment, it may be electrically too noisy for wireless heart rate measurement.
Technical Specifications
Training System
The wrist unit is a class 1 Laser Product
Battery life: Battery type: Battery sealing ring: Operating temperature:
Materials:
Watch accuracy:
Accuracy of heart rate monitor:
Heart rate measuring range:
Average 1 year (1h/day, 7 days/week) CR 2354
Thermoplastic polymer
Better than ± 0.5 seconds / day at 25 °C / 77 °F temperature.
±1% or 1 bpm, whichever larger. Definition applies to stable conditions.
15‐240
Current speed display range: | |
Altitude display range: |