CONTROLS AND FEATURES
DC Receptacle and Fuse
The DC receptacle is protected from |
|
an overload with a fuse. If the DC | F1 |
circuit is overloaded, the 5 amp fuse | |
(F1) will blow and power to the DC |
|
receptacle will cease. The red light |
|
on the DC panel will illuminate. The |
|
fuse is located to the left of the |
|
receptacle and is accessed by |
|
snapping open the access door. |
|
Replace the fuse with one of the |
|
same capacity. Using a higher rated |
|
fuse may cause damage to the |
|
generator alternator. |
|
F2
The DC receptacle (F2) may be used for charging 12 volt automotive- type batteries only. It is not designed to operate DC motors. Output voltage is
AC Receptacles
Two AC receptacles (I) provide two connections for properly rated AC appliances. The two AC receptacles are rated at 20 amps.