TROUBLESHOOTING
Troubleshooting Symptoms
POSSIBLE LEAN | SOLUTION | |
FUEL CAUSE | ||
| ||
|
| |
Low or contaminated fuel | Add fuel, or drain the fuel system and refuel | |
|
| |
Kinked or plugged fuel tank | Inspect and replace | |
vent |
| |
|
| |
Low octane fuel | Drain the fuel system and refuel | |
|
| |
Carburetor jetting incorrect | Take the generator to an authorized POLARIS servicing | |
| supplier or refer to the service manual | |
|
| |
|
| |
POSSIBLE RICH | SOLUTION | |
FUEL CAUSE | ||
| ||
|
| |
Incorrect fuel | Drain the fuel system and refuel | |
|
| |
Stopping / starting without | Allow the engine to warm up before operating and / or | |
adequate | stopping | |
|
| |
Incorrect spark plug | Inspect and replace with correct plug | |
|
| |
Clogged air filter | Inspect and clean or replace | |
|
| |
No Power at DC Receptacle | ||
|
| |
POSSIBLE CAUSE | SOLUTION | |
|
| |
Is the fuse blown | Replace the fuse. | |
|
| |
Faulty generator | Take the generator to an authorized POLARIS servicing | |
| supplier or refer to the service manual | |
|
|
70