OPERATION
Safe Operating Precautions
DC Operation
Connecting the Battery Charging Cable
Do not start the vehicle while the battery charging cable is connected and the generator is running. The vehicle’s charging system or the generator may be damaged.
Note: The DC receptacle is protected from an overload with a fuse. If the DC circuit is overloaded, the 5 amp fuse will blow and power to the DC receptacle will cease. The red light on the DC panel will illuminate. If the DC overload fuse continues to blow, discontinue charging and see your authorized POLARIS generator supplier. The overload fuse does not prevent overcharging the battery. The fuse is located to the left of the receptacle and is accessed by snapping open the access door. Replace the fuse with one of the same capacity. Using a higher rated fuse may cause damage to the generator alternator.
Disconnecting the Battery Charging Cable
1.Stop the generator.
2.Disconnect the black lead of the battery charging cable from the negative
3.Unplug the battery charging cable from the DC receptacle.
4.Connect the vehicle battery ground cable to the negative