TROUBLESHOOTING
Troubleshooting Symptoms
No Power at AC Receptacles
POSSIBLE CAUSE | SOLUTION |
|
|
Output indicator is OFF, and | Take the generator to a POLARIS servicing supplier or |
overload indicator is ON | refer to the service manual |
|
|
AC circuit protector tripped | Check AC load and reset circuit protector |
|
|
Overload protector tripped | Push the Overload Restart switch |
|
|
Faulty power tool or appli- | Replace or repair power tool or appliance; stop and |
ance | restart the engine |
|
|
Faulty generator | Take the generator to an authorized POLARIS servicing |
| supplier or refer to the service manual |
|
|
Engine Stops or Loses Power
POSSIBLE CAUSE | SOLUTION |
|
|
Out of fuel | Refuel |
|
|
Fouled, worn, incorrect, or | Inspect, clean, and / or replace the spark plug / set the |
defective spark plug; incor- | spark plug gap to specification |
rect spark plug gap or heat |
|
range |
|
|
|
Loose ignition connections | Check all connections and tighten |
|
|
Water present in fuel / | Drain the fuel system and refuel |
incorrect fuel |
|
|
|
Kinked or plugged fuel tank | Inspect and replace |
vent line |
|
|
|
Economy throttle control | Take the generator to an authorized POLARIS servicing |
malfunction | supplier or refer to the service manual |
|
|
No / low oil in the engine | Check / replace oil |
|
|
Clogged air filter | Clean or replace the air filter |
|
|
Overheated engine | Clean cover screens |
|
|
Mechanical failure | Take the generator to an authorized POLARIS servicing |
| supplier or refer to the service manual |
|
|