Starting the Engine
6. To start the generator using the ignition | OFF |
key, turn the ignition switch to the | |
START position. When the engine |
|
starts, release the key. Do not operate |
|
the starter for more then 10 second |
|
intervals. If it doesn’t start turn the key |
|
to the OFF position for 5 seconds before |
|
repeating until it starts. |
|
7.To start the generator, using the recoil, lightly pull the starter recoil grip until resistance is felt. Then, firmly pull straight out.
ON
START
Do not allow starter grip to snap back against the generator. Return it gently to prevent damage to the starter.
8. If the choke knob was positioned to CLOSE to start the engine, move it to OPEN as the engine warms up.
OPEN
9.After a 2 to