MAINTENANCE
Battery
Battery Charging (Sealed Only)
Note: This procedure applies only to the sealed battery (recommended).
1.Using a voltmeter or
2.If the voltage is less than 12.8V DC, recharge the battery at 1.2 amps or less until the battery voltage is 12.8V DC or greater.
|
|
| CHARGE TIME | |
STATE OF |
|
| (Using constant | |
VOLTAGE | ACTION | current charger @ | ||
CHARGE | standard amps | |||
|
| |||
|
|
| specified on top of | |
|
|
| battery) | |
|
|
|
| |
100% | 12.8 - 13.0 Volts | None. Check at 3 months from | None required | |
|
| manufacture date. |
| |
|
| May need slight charge, if no |
| |
75% - 99% | 12.5 - 12.7 Volts | charge given, check in 3 | 3 - 6 hours | |
|
| months. |
| |
|
|
|
| |
50% - 74% | 12.0 - 12.4 Volts | Needs charge | 5 - 11 hours | |
|
|
|
| |
|
|
| At least 13 hours, | |
25% - 49% | 11.5 - 11.9 Volts | Needs charge | verify state of | |
|
|
| charge | |
|
|
|
| |
0% - 24% | 11.4 volts or less | Needs charge with de- | At least 20 hours | |
|
| sulfating charger |
|
56