Porter-Cable D24225-049-2 instruction manual To Drain Tank, Oil, Checking, Changing

Models: D24225-049-2

1 80
Download 80 pages 52.51 Kb
Page 16
Image 16

To Drain Tank

NOTE: Operation of the air compressor will cause condensation to build up in the air tank. Always drain tank on a washable surface or in a suitable container to prevent damaging or staining surfaces.

1.Set the On/Auto/Off lever to "OFF".

2.Close the globe valve.

3.Remove the air tool or accessory.

4.Open the globe valve and allow the air to slowly bleed from the air tank until tank pressure is approximately 20 psi.

5.Close the globe valve.

6.Drain water from air tank by opening drain valve (counter-clockwise) on bottom of tank.

Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air

tank rupture.

7.After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

Oil

Checking

1.The oil level should be to the middle of the sight glass (C).

2.If needed remove oil fill plug (A) and slowly add oil until it reaches the middle of the sight glass.

NOTE: Use a air compressor oil such as SAE-30 (API CG/CD heavy duty motor oil). Under extreme winter conditions use SAE-20 weight oil.

Changing

1.Remove the oil fill plug (A).

2.Remove the oil drain plug (B) and drain oil into a suitable container.

3.Replace the oil drain plug (B) and tighten securely

NOTE: Use a air compressor oil such as SAE-30 (API CG/CD heavy duty motor oil). Under extreme winter conditions use SAE-20 weight oil.

4.Slowly add compressor oil until the oil level is in the middle of the sightglass (B). NOTE: When filling the crankcase, the oil flows very slowly into the pump. If the oil is added too quickly, it will overflow and appear to be full. NOTE: Crankcase oil capacity is approximately 40 fluid ounces (1.2 L).

Overfilling with oil will cause premature compressor failure.

Do not overfill.

5.Replace oil fill plug (A) and tighten securely.

C

B

A

D24225

16- ENG

Page 16
Image 16