7.Check for excessive vibration. Readjust or shim air compressor feet, if necessary.

8.After 20 minutes, close the globe valve.The air receiver will fill to "cut-out" pressure and the motor will stop.

Before Each Start-Up:

1.Place On/Auto/Off lever to "OFF".

2.Close the globe valve.

3.Attach hose and accessories. NOTE: A regulator MUST be installed when using accessories rated at less than 175 PSI.

Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure

rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start

1.Turn the On/Auto/Off lever to "AUTO" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.When the tank pressure reaches "cut-out" pressure open the globe valve.

IMPORTANT: When using regulator and other accessories refer to the manufacturer-s instructions.

NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer, DO NOT place compressor near the spray area.

D24225

14- ENG

Page 14