FURTHER TECHNICAL INFORMATION

PRINTER SETUP

On bottom cover of the Aura series thermal printer, there is screwed a metal plate for setup window. In this window, there is a 8 position DIP switch for printer setup. Please use proper tool to change the switch setting when necessary. The switch position counting starts from the nearest edge of printer. The

ON direction points to the connector area of the printer. The OFF direction points to the power switch. The functions of each position may evolve with the revisions of the firmware. The information below applies to the latest version to the date of print of this manual.

This 8 position DIP switch works as following:

Switch

ON

OFF

position

 

 

1

RS232 baud rate definition

or Parallel interface definition (ref.

2

separate table below)

3

Even parity

None parity

4

XON/XOFF handshaking

DSR/DTR handshaking

5

Busy on “buffer full”

Busy on “buffer full” and/or “off line”

6

Cut without paper feed

Cut with auto paper feed

7

CR code (0Dh) effective

CR code (0Dh) invalid

8

Factory internal setting

Application standard mode

Effect of positions 1 & 2 on baud rate is defined as in table below with parity check set according to position 3, number of data bits always set to 8, and stop bit set to 1. When the interface used is anything other than RS232, please still set these 2 switches at exactly the specified combination.

SW Pos. 1

ON

OFF

ON

OFF

SW Pos. 2

ON

ON

OFF

OFF

Baud rate setup

38400 bps

115200 bps (Default)

9600 bps

19200 bps

Switch position 3 defines the parity check regulation in serial interface. In Aura, it is selectable between even and none.

Switch position 4 defines the handshaking method in serial interface. When it is set to ON, the printer transmits an “XOFF” for busy and sends an “XON” for not busy. When it is set to OFF, the printer signifies the busy status over hardware signals that can be detected by the host as “DSR” or “CTS”. When parallel interface is used, both switch positions 3 and 4 should be set to OFF.

For switch position 5, if the switch is set to ON, the busy signal is sent