Trouble

Probable Cause

Remedy

 

 

 

 

 

If electric motor is suspect, have it

Machine will not

Motor failure.

tested by qualified service personnel.

start/restart or

 

Repair or replace as needed.

repeatedly trips

 

 

 

Double check to confirm all electrical

circuit breaker or

 

 

connections are correct. Refer to

blows fuses.

Electrical leads are attached

appropriate wiring diagrams on pages

 

incorrectly.

 

36 through 38 to make any needed

 

 

 

 

corrections.

 

 

 

 

 

Inspect all motor leads for tightness.

 

Loose electrical connections.

Look for any signs of electrical arcing

 

which would indicate loose

 

 

 

 

connections or circuit overload.

 

 

 

 

 

If the on/off switch is suspect, you

 

 

have two options: Have a qualified

 

On/off switch failure.

electrician test the switch for function,

 

or purchase a new on/off switch and

 

 

 

 

establish if that was the problem on

 

 

changeout.

 

 

 

Optional Accessories

2042376

Mobile Base

6296046

Knives (set of 3)

6285917

Push Block

Replacement Parts

Replacement parts are listed on the following pages. To order parts or reach our service department, call 1-800-274-6848 between 7:30 a.m. and 6:00 p.m. (CST), Monday through Friday. Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately.