SINGLE-PHASE SERIES 9

Powerware 9170+ (continued)

SOFTWARE AND CONNECTIVITY OPTIONS

Bundled with Software Suite CD and communication cable. See the software and connectivity product section for more detail.

Universal Module ASY-0674 Runtime Chart in minutes (full load/half load)

Load (VA) Number of strings (2 battery modules per string; 2 battery modules occupy 1-slot)

 

1 String

2 String

3 String

4 String

5 String

6 String

7 String

8 String

9 String

10 String

11 String

12 String

3 kVA

8/24

24/59

43/95

58/140

80/175

95/125

119/240

135/290

155/335

165/365

200/395

215/450

6 kVA

 

8/24

16/40

24/59

32/83

40/103

49/114

58/140

69/156

83/175

90/190

103/205

9 kVA

 

 

8/24

13/35

18/46

24/59

29/63

35/86

40/103

46/115

54/125

58/140

12 kVA

 

 

 

8/24

13/33

16/40

19.5/43.5

24/59

29/70

33/80

36/90

41/100

15 kVA

 

 

 

 

8/24

11.5/31

14.5/31.5

18/46

20.5/51

24/58

28/66

31/73

18 kVA

 

 

 

 

 

8/24

11/31.5

13/36

15.5/41

18/45

20.5/51

24/58

Additional battery runtimes available up to 8 hours. Please contact your Powerware representative.

 

13 String

14 String

15 String

16 String

17 String

18 String

19 String

20 String

21 String

22 String

23 String

24 String

3 kVA

225/500

245/540

270/600

290/620

315/650

335/690

350/720

365/780

375/850

395/890

425/920

450/950

6 kVA

113/335

123/255

135/273

143/290

148/315

156/333

165/350

175/365

183/385

190/395

198/420

205/440

9 kVA

63/150

73/165

80/178

86/190

93/200

100/210

107/225

115/240

121/255

125/270

135/280

143/290

12 kVA

47/110

52/121

56/130

58/140

65/147

70/156

75/165

80/175

85/185

90/195

95/205

100/215

15 kVA

34/83

38/94

41.5/103

44.5/113

46.5/117

51/127

56/130

58/140

61/149

66/158

71/165

73/170

18 kVA

27/65

31.5/72

34.5/77

36/83

38/94

41/100

44/105

45/115

48/122

54/131

57/137

58/140

Battery strings above and to the right of the dark line require additional (N+X) power modules or a 20A charger module.

Split-phase Module ASY-0673 Runtime Chart in minutes (full load/half load)

Load (VA) Number of Strings (2 battery modules per string; 2 battery modules occupy 1-slot)

 

1 String

2 String

3 String

4 String

5 String

6 String

7 String

8 String

9 String

10 String

11 String

12 String

3 kVA

6.5/16

16/40

27.5/67.5

40/98

53.5/132

67.5/167

83/204

98/242

115/283

132/324

149/365

167/408

6 kVA

 

6.5/16

11/27.5

16/40

21.5/53.5

27.5/68

33.5/83

40/98

46.5/115

53.5/132

60.5/149

67.5/167

9 kVA

 

 

6.5/16

9.5/23.5

13/31.5

16/40

20/49

23.5/58

27.5/67.5

31.5/78

35.5/88

40/98

12 kVA

 

 

 

6.5/16

9/21.5

11/27.5

13.5/33.5

16/40

19/46.5

21.5/53.5

24.5/60.5

27.5/68

15 kVA

 

 

 

 

6.5/16

8/20.5

10/25

12/30

14/35

16/40

18.5/45

20.5/50.5

18 kVA

 

 

 

 

 

6.5/16

8/20

9.5/23.5

11/27.5

12.5/30

14.5/35.5

16/40

Additional battery runtimes available up to 8 hr. Please contact your Powerware representative. Split-phase Module is for U.S. use.

 

13 String

14 String

15 String

16 String

17 String

18 String

19 String

20 String

21 String

22 String

23 String

24 String

3 kVA

185/456

204/501

223/549

242/595

262/640

283/692

302/750

323/790

345/850

365/900

387/955

408/1015

6 kVA

75/185

83/204

90/223

98/242

106/262

115/285

123/302

132/324

140/345

149/365

157/388

167/408

9 kVA

44/109

49/120

53.5/132

58/143

63/154

68/167

73/179

78/191

83/204

88/210

93/229

98/242

12 kVA

30.5/75

33.5/83

37/90

40/98

43/106

46.5/115

50/123

53.5/132

57/140

60/149

64/157

68/167

15 kVA

23/56

25/62

27.5/67.5

30/73.5

32.5/79.5

35/86

37.5/92

40/98

42.5/105

45/111

48/118

51/124

18 kVA

18/44

20/49

21.5/53.5

23.5/58

25.5/63

27.5/68

29.5/73

31.5/78

33.5/83

35.5/88

38/93

40/98

Battery strings above and to the right of the dark line require additional (N+X) power modules or a 20A charger module.

Customizable Input Plug Options1

Input Plug

Power Module Type

CTO Digit

List Price

L6-30P2

Universal

C

$109

L14-20P3

Split-Phase

F

$109

L14-30P2

Split-Phase

G

$129

14-50P4

Split-Phase

H

$149

1.May be configured to order through or sales office: 800.356.5794. 2. Limits chassis to maximum current of 24A and three power modules for 5 kVA redundant. 3. Limits chassis to maximum current of 16A and two power modules for 3 kVA redundant. 4. Limits chassis to maximum current of 40A and four power modules for 8 kVA redundant.

www.powerware.com 1.800.356.5794

47

Page 49
Image 49
Powerware 1500 VA - 60kVa Customizable Input Plug Options1, String, Input Plug Power Module Type CTO Digit List Price

1500 VA - 60kVa specifications

The Powerware 1500 VA - 60 kVA is a robust uninterruptible power supply (UPS) solution designed to provide reliable power protection for critical applications across various environments. With a power range that spans from 1.5 kVA to 60 kVA, this UPS is capable of catering to the diverse needs of modern businesses and organizations, ensuring uninterrupted operations even in the face of power disturbances.

One of the main features of the Powerware 1500 VA - 60 kVA is its advanced double-conversion technology. This technology allows for continuous power conditioning, ensuring that the output power is always clean and stable. By converting incoming AC power to DC and then back to AC, the UPS eliminates voltage fluctuations and protects sensitive electronic equipment from surges, sags, and other electrical anomalies.

The system is equipped with various connectivity options, including USB and serial communication ports, which facilitate easy monitoring and management of power settings. With user-friendly interfaces, operators can quickly access vital information about the UPS’s performance, battery status, and load levels. Additionally, options for network management cards allow for remote monitoring, which is essential for data centers or facilities that require constant oversight of their power systems.

Another notable characteristic of the Powerware 1500 VA - 60 kVA is its scalability. Users can seamlessly expand the UPS capacity by adding additional power modules, making it a future-proof investment that can grow alongside the organization. This feature is particularly valuable for businesses anticipating growth or increased power demands in the future.

The Energy Saver System (ESS) technology integrated into the Powerware series helps to optimize energy efficiency, reducing operating costs while maintaining high performance. By using smart algorithms to minimize losses, the UPS can operate in eco-friendly modes without compromising reliability.

Furthermore, the Powerware UPS units are designed with high availability in mind, featuring hot-swappable batteries and modular designs that allow for easy maintenance without interrupting the power supply. This high-reliability design ensures that operations remain consistent and that downtime is minimized.

Overall, the Powerware 1500 VA - 60 kVA UPS is an exceptional choice for businesses seeking a dependable power protection solution. With its advanced technologies, scalability, and energy efficiency features, it meets the demands of critical applications while delivering consistent performance and reliability.