Powerware 1500 VA - 60kVa manual Powerware 9355 10-15 kVA, Powerware 9355 Bypass Cabinets

Models: 1500 VA - 60kVa

1 120
Download 120 pages 4.93 Kb
Page 60
Image 60

THREE-PHASE SERIES 9

Powerware 9355 (10–15 kVA) (continued)

POWERWARE 9355 BYPASS CABINETS

 

Part

Power

Input/Output

Dimensions

Weight

List

Model

Number

Rating

Voltage

(H x W x D, inches)

(lb)

Price

PW9355 15kVA 3-Breaker Maintenance Bypass Panel

124100027-001

NA

208V/208V

48 x 20 x 5.8

300

$3,450

(100A Bus, 200A Neutral, & 60A MBP, MIB, MIS)

 

 

 

 

 

 

PW9355 15kVA 3-Breaker Maintenance Bypass Panel

124100027-002

NA

208V/208V

60 x 20 x 5.8

350

$6,548

with integral 120 KA TVSS (100A Bus, 200A Neutral,

 

 

 

 

 

 

& 60A MBP, MIB, MIS)

 

 

 

 

 

 

PW9355 15kVA 3-Breaker Maintenance Bypass Panel

124100027-003

NA

208V/208V

72 x 20 x 5.8

450

$3,850

with 36-Pole Distribution Provisions (Cutler-Hammer GHB 65 kAIC,

 

 

 

 

 

 

GBHW 22 kAIC, & BAB 10 kAIC ONLY)

 

 

 

 

 

 

PW9355 15kVA 3-Breaker Maintenance Bypass Panel

124100027-004

NA

208V/208V

90 x 20 x 5.8

500

$7,100.

SURGE PROTECTION

See the surge protection product section for more details.

OUTPUT RECEPTACLES

Receptacle Codes

(Qty) NEMA Type

Enter “Receptacle Code” into CTO Digits #

Price Adder for EACH Receptacle Code Chosen

2

(1)

L15-30R

9, 10 or 11 only

$220

3

(1)

L21-20R

9, 10 or 11 only

$220

4

(1)

L21-30R

9, 10 or 11 only

$220

A

(2)

5-15R

9,10,11,12

$220

B

(2)

5-20R UL

9,10,11,12

$220

D

(2)

6-15R

9,10,11,12

$220

E

(2)

6-20R

9,10,11,12

$220

F

(2)

L5-15R

9,10,11,12

$220

G

(1)

L5-20R*

9,10,11,12

$220

H

(1)

L5-30R*

9,10,11,12

$220

I

(2)

L6-15R

9,10,11,12

$220

J

(1)

L6-20R*

9,10,11,12

$220

K

(1)

L6-30R*

9,10,11,12

$220

L

(1)

L14-20R*

9,10,11,12

$220

M

(1)

L14-30R*

9,10,11,12

$220

X

Blank Panel

9,10,11,12

$20

N

(2)

IEC 320 C13 (120V)

9,10,11,12

$220

P

(2)

IEC 320 C19 (120V)

9,10,11,12

$220

Note: Arrange receptacle codes in numerical-alphabetical order in digits 9 through 12 of the CTO number

Example 1: a PDM with an L21-20, an L14-30, and Qty 2 IEC320-C19 would have digits 9 through 12 of the CTO arranged as "3MPP"

Example 2: a PDM with a 5-15R, and an L6-30, and an L14-30 would have digits 9 through 12 of the CTO arranged as “AKMX”

The combined quantities of LOCKING receptacles (denoted by *) must not exceed 4 per unit.

Please be sure utilize the "X" designation for any of the 4 total slots not populated.

ON-BOARD CONNECTIVITY OPTIONS

 

 

Part Number

Value for

Price

 

Utilize digit 8 in CTO number

(if ordered seperately)

CTO digit 8

Adder

 

NONE (No Pre-installed X-Slot card)

 

0

$0

ConnectUPS-X Web/SNMP Card

 

3

$335

Modem Card

 

7

$530

Modbus Card

 

4

$661

Relay Card (AS/400 compatible)

 

5

$146

Industrial Relay Card

 

6

$335

Note: You can have up to two optional connectivity cards installed.

SERVICE PLANS

For service plans, please see the service section beginning on page 88.

58 EATON CORPORATION Reference Guide & Price Book

Page 60
Image 60
Powerware 1500 VA - 60kVa Powerware 9355 10-15 kVA, Powerware 9355 Bypass Cabinets, Surge Protection, Output Receptacles

1500 VA - 60kVa specifications

The Powerware 1500 VA - 60 kVA is a robust uninterruptible power supply (UPS) solution designed to provide reliable power protection for critical applications across various environments. With a power range that spans from 1.5 kVA to 60 kVA, this UPS is capable of catering to the diverse needs of modern businesses and organizations, ensuring uninterrupted operations even in the face of power disturbances.

One of the main features of the Powerware 1500 VA - 60 kVA is its advanced double-conversion technology. This technology allows for continuous power conditioning, ensuring that the output power is always clean and stable. By converting incoming AC power to DC and then back to AC, the UPS eliminates voltage fluctuations and protects sensitive electronic equipment from surges, sags, and other electrical anomalies.

The system is equipped with various connectivity options, including USB and serial communication ports, which facilitate easy monitoring and management of power settings. With user-friendly interfaces, operators can quickly access vital information about the UPS’s performance, battery status, and load levels. Additionally, options for network management cards allow for remote monitoring, which is essential for data centers or facilities that require constant oversight of their power systems.

Another notable characteristic of the Powerware 1500 VA - 60 kVA is its scalability. Users can seamlessly expand the UPS capacity by adding additional power modules, making it a future-proof investment that can grow alongside the organization. This feature is particularly valuable for businesses anticipating growth or increased power demands in the future.

The Energy Saver System (ESS) technology integrated into the Powerware series helps to optimize energy efficiency, reducing operating costs while maintaining high performance. By using smart algorithms to minimize losses, the UPS can operate in eco-friendly modes without compromising reliability.

Furthermore, the Powerware UPS units are designed with high availability in mind, featuring hot-swappable batteries and modular designs that allow for easy maintenance without interrupting the power supply. This high-reliability design ensures that operations remain consistent and that downtime is minimized.

Overall, the Powerware 1500 VA - 60 kVA UPS is an exceptional choice for businesses seeking a dependable power protection solution. With its advanced technologies, scalability, and energy efficiency features, it meets the demands of critical applications while delivering consistent performance and reliability.