Powerware Powerware 9390 manual UPS Sidecar Standard Features, Options

Models: Powerware 9390

1 124
Download 124 pages 14.91 Kb
Page 33
Image 33

Chapter 4

UPS Sidecar Features, Controls, and Operation

4.1UPS Sidecar Standard Features

The UPS Sidecar has many standard features that provide cost-effective and consistently reliable power distribution. The descriptions provide a brief overview of the UPS Sidecar controls, and standard and optional features.

4.1.1Maintenance Bypass Configuration

A Maintenance Bypass switch (MBP), in combination with the Maintenance Isolation switch (MIS), can be used to completely isolate the UPS during service. The UPS can be serviced or replaced without interrupting power to critical systems.

4.1.2Parallel Redundant Configuration

Module Output Breakers 1 and 2 enable two UPS modules to be paralleled together for redundancy. An optional System Load Breaker provides output control to the critical load for the whole system.

4.1.3Customer Interface

The UPS Sidecar uses one UPS building alarm input for Maintenance Bypass Switch Monitoring. The building alarm is used to detect when the Maintenance Bypass switch is closed and the system is on bypass.

4.1.4Installation Features

The UPS Sidecar is factory-installed to the side of the UPS cabinet. Power wiring can be routed through the top or bottom of the cabinet with connections made to easily accessible terminals. Parallel redundant modules can be installed in line-up-and-matchor standalone configurations. Line-up-and-match cabinets are wired through the side panels of the units.

4.1.5Expansion

The UPS Sidecar supports custom configurations and scalability to adapt to changing and future power and distribution needs. See paragraph 4.2 for available options.

4.2Options

Contact your sales representative for information about any of these available options:

4.2.1Bypass Input Breaker (BIB)

Maintenance bypass configurations have an optional BIB for single-feed and dual-feed systems. The BIB provides a single point of input power control to the UPS and easily removes power from the UPS for servicing.

EATON Powerware® 9390 UPS Sidecar Installation and Operation Manual S 164201586 Rev E www.powerware.com

4-1

Page 33
Image 33
Powerware Powerware 9390 manual UPS Sidecar Standard Features, Options

Powerware 9390 specifications

The Powerware 9390 is a high-performance uninterruptible power supply (UPS) that has been designed for mission-critical applications, providing reliable power protection and ensuring the continuous operation of sensitive equipment. It is particularly well-suited for data centers, telecommunications, and healthcare environments, where power reliability is paramount.

One of the standout features of the Powerware 9390 is its impressive scalability. This UPS is available in various capacities, typically ranging from 80 kVA to 500 kVA, allowing organizations to select a model that perfectly aligns with their power requirements. The modular design of the Powerware 9390 enables users to expand their system easily, accommodating future growth without significant investments in new equipment.

Another significant characteristic of the Powerware 9390 is its high efficiency. The UPS is equipped with advanced technologies that deliver exceptional energy efficiency, often exceeding 94% during normal operating conditions. This high efficiency not only reduces operational costs but also minimizes the carbon footprint of organizations, making the Powerware 9390 an environmentally friendly choice.

The unit offers advanced digital signal processing (DSP) technology, enhancing the unit's performance and ensuring that it can handle varying load conditions effectively. The Powerware 9390 is designed to provide a high level of protection against power disturbances and outages, including voltage sags, surges, and frequency variations.

The Powerware 9390 incorporates a user-friendly interface, featuring an intuitive LCD display that provides real-time information on system status, operational parameters, and alarms. This transparency allows facility managers to monitor the UPS at a glance and take necessary actions when required.

Additionally, for enhanced reliability, the Powerware 9390 supports a hot-swappable battery configuration. This feature is particularly beneficial as it enables battery replacement without disrupting the power supply, thus maintaining continuous operation during maintenance.

Moreover, the UPS supports various communication protocols, allowing integration with building management systems and enabling remote monitoring capabilities. This feature is crucial for operators who need to keep a constant eye on power conditions and ensure optimal performance.

In summary, the Powerware 9390 stands out as a robust, efficient, and scalable UPS solution. Its advanced technologies and features cater to the power protection needs of critical applications, making it an ideal choice for organizations that demand reliability and efficiency in their power systems. With its combination of scalability, energy efficiency, user-friendly interface, and robust protection capabilities, the Powerware 9390 continues to be a preferred solution for many industries worldwide.