Pride Mobility 1100 owner manual Thermal Rollback, Trouble Codes

Models: 1100

1 60
Download 60 pages 56.57 Kb
Page 31
Image 31

V I I I . O P E R A T I O N

CAUTION! Failure to properly align the connectors can result in damage to the Pilot, the charger, and the connectors.

Thermal Rollback

The Pilot is equipped with a thermal rollback circuit. This circuit monitors the temperature of the motors and the Pilot. In the event that either one of the motors or the Pilot becomes excessively hot (above 122° F), the Pilot reduces the motor voltage. For every degree above 122° F, the controller reduces the voltage by 5 volts. This reduces your power chair’s speed and allows the electrical components to cool down. When the temperature returns to a safe level, your power chair resumes its normal speed.

WARNING! Under strenuous driving conditions, it is possible for the bottom and side case temperature of the Pilot to exceed 105° F. DO NOT touch the side or bottom of the Pilot case under these circumstances.

Trouble Codes

In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems with your power chair. The battery condition meter has ten lights. The lights provide information by the number of lights that are flashing. If any of the meter lights are flashing rapidly, the controller may be indicating a fault. For instance, if the first light is flashing rapidly, the battery voltage is nearly depleted. The following is a list of the possible errors signified by the rapidly flashing meter. When you get a trouble code, contact your authorized Pride provider.

FLASHING

DIAGNOSIS

SOLUTION

LIGHTS

 

 

10

High Battery Voltage

Check batteries.

 

 

 

9

Solenoid Brake Fault

Check motor/brake wiring.

 

 

 

8

Possible Controller Fault

See authorized Pride provider.

 

 

 

7

Possible Joystick Fault

See authorized Pride provider.

 

 

 

6

Inhibit Active

Unplug charger. Check connections.

 

 

 

5

Right Motor Wiring Fault

Check right motor wiring.

 

 

 

4

Right Motor Disconnected

Check right motor wiring.

 

 

 

3

Left Motor Wiring Fault

Check left motor wiring.

 

 

 

2

Left Motor Disconnected

Check left motor wiring.

 

 

 

1

Low Battery Voltage

Check batteries/battery wiring.

 

 

 

Jazzy 1100/RevJ/Feb03

www.pridemobility.com

31

Page 31
Image 31
Pride Mobility 1100 owner manual Thermal Rollback, Trouble Codes