X . C A R E A N D M A I N T E N A N C E

BATTERY REPLACEMENT

A diagram is printed on a decal on the Jazzy 1100 frame near the battery tray.

WARNING! Battery posts, terminals, and related accessories contain lead and lead com- pounds. Wear goggles and gloves when handling batteries and wash hands after han- dling.

WARNING! Pride Power Chair batteries are heavy. See the specification table. If you are unable to lift that much weight, be sure to get help. Lifting beyond your capacity can result in personal injury.

To replace the batteries:

1.

Turn the power off.

 

 

 

2.

Unplug the controller wire harness.

 

 

 

3.

Remove the seat.

 

 

 

4.

Remove the shroud.

 

 

 

5.

Loosen the wing nuts on the positive (red) battery termi-

 

 

 

 

nals first.

 

 

 

 

 

 

 

6.

Remove the wires.

 

 

 

7.

Loosen the wing nuts on the negative (black) battery ter-

 

 

 

MOTOR BRUSH CAP

 

minals.

 

 

 

 

8.

Remove the wires.

Figure 43. Motor Brush Cap

9.

Replace the batteries.

 

 

 

10.Install the batteries into your Jazzy 1100 with the terminal sides of the batteries facing inward, towards each other.

11.Connect the wire marked (+) to the closest positive (red) battery terminal.

12.Connect the wire marked (-) to the closest negative (black) battery terminal on the other battery.

13.Connect one circuit breaker harness to the empty positive terminal of one battery, and connect the other circuit breaker harness to the empty negative terminal of the other battery.

WARNING! Make sure you tighten the fasteners so that the connections are secure.

MOTOR BRUSHES

The electric motors that power your Jazzy 1100 use carbon brushes. These brushes may become susceptible to wear over a long period of time. The motor brushes are the two contacts located inside the motor assembly that supply power to the motor. They are designed to provide several thousand hours of operation. However, if the brushes become dirty with carbon deposits or wear out, the motor will run poorly or not at all.

CAUTION! If inspection determines excessive wear on the brushes, they must be replaced or motor damage will result. Failure to maintain the brushes could void your Jazzy 1100’s warranty.

To inspect or replace the motor brushes:

1.Remove the seat, body shroud, and batteries. See VII. “Disassembly.”

2.Unscrew the motor brush caps. See figure 43.

3.Remove the brushes.

4.Inspect for wear.

5.Replace brushes, if necessary. Contact your local authorized Pride provider for replacement brushes.