Flash Memory Message Guide

Flash Memory Message Guide

Message

Explanation

Required Action

 

 

 

 

 

 

CLEARING PROGRAM

The program successfully

None

FROM FLASH

loaded into printer RAM and

 

 

the checksum matched. The

 

 

old program is now being

 

 

deleted from flash memory.

 

 

 

 

DIAGNOSTIC PASSED

The printer passed its

None

 

memory and hardware

 

 

initialization tests.

 

 

 

 

ERROR: DC PROGRAM

Printer cannot find the data

1. Download the program

NOT VALID

controller program or the

again.

 

validation checksum is

2. If the message occurs

 

corrupt.

 

again, replace the flash

 

 

 

 

memory.

 

 

 

ERROR: DRAM AT

The printer found a defective

Replace the DRAM.

ADDRESS XXXXXXXX

memory location.

 

 

 

 

ERROR: EC PROGRAM

Printer cannot find the engine

1. Download the program

NOT VALID

controller program or the

again.

 

validation checksum is

2. If the message occurs

 

corrupt.

 

again, replace the flash

 

 

 

 

memory.

 

 

 

ERROR: EC STOPPED AT

Hardware fault in the engine

Replace the CMX controller

STATE XXXX

controller.

board.

 

 

 

ERROR: FLASH DID NOT

The printer could not find any

1. Download the program

PROGRAM

flash memory.

again.

 

 

2. If the message occurs

 

 

again, replace the flash

 

 

memory.

 

 

 

ERROR: FLASH NOT

The printer could not find any

Install flash memory before

DETECTED

flash memory.

attempting to download this

 

 

program.

 

 

 

ERROR: NO DRAM

The printer could not find any

Check DRAM on CMX. If

DETECTED

DRAM.

present, reseat DRAM. If

 

 

missing, install DRAM.

 

 

 

ERROR: NVRAM FAILURE

The non-volatile memory has

Replace the CMX controller

 

failed.

board. (Do NOT attempt to

 

 

replace NVRAM.)

 

 

 

ERROR: PROGRAM NEEDS

The printer requires more

Add DRAM or use a smaller

MORE DRAM

DRAM memory in order to run

emulation program.

 

the downloaded program.

 

 

 

 

19

Page 19
Image 19
Printronix ANSI Printer manual Flash Memory Message Guide, Message Explanation Required Action