TROUBLESHOOTING

TROUBLESHOOTING

Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please see the front cover of this manual. PROBLEM: The power does not turn on

SOLUTION: a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppressor

is plugged into a properly grounded outlet (see page 12). Use only a single-outlet surge suppres-

sor that meets all of the specifications described on page 12. IMPORTANT: The treadmill is not

compatible with GFCI-equipped outlets.

 

 

b. After the power cord has been plugged in, make sure that the key is inserted into the console.

c. Check the reset/off circuit breaker located on the

c

 

treadmill frame near the power cord. If the switch

 

protrudes as shown, the circuit breaker has

 

 

tripped. To reset the circuit breaker, wait for five

Tripped

Reset

minutes and then press the switch back in.

PROBLEM: The power turns off during use

 

 

SOLUTION: a. Check the reset/off circuit breaker (see the drawing above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.

b.Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for five minutes, and then plug it back in.

c.Remove the key from the console. Reinsert the key into the console.

d.If the treadmill still will not run, please see the front cover of this manual.

PROBLEM: The console displays remain lit when you remove the key from the console

SOLUTION: a. The console features a display demo mode, designed to be used if the treadmill is displayed in a

store. If the displays remain lit when you remove the key, the demo mode is turned on. To turn off

the demo mode, hold down the Stop button for a few seconds. If the displays are still lit, see THE

INFORMATION MODE on page 20 to turn off the demo mode.

 

PROBLEM: The displays of the console do not function properly

 

 

SOLUTION: a. Remove the key from the console and UNPLUG

a

78

THE POWER CORD. With the help of a second

person, carefully tip the Uprights (77, 78) down.

 

 

There may be three #8 x 2" Screws (110) in the

 

 

bottom of the Belly Pan (76). If there are, remove

 

 

them. Note: A Phillips screwdriver with a shaft at

77

76

least 5 in. (13 cm) long is required.

 

 

110

 

 

110

22

Page 22
Image 22
ProForm PFTL06009.0 Troubleshooting, compatible with GFCI-equipped outlets, PROBLEM The power turns off during use