Promise Technology J310S, J610S manual Drive Type SAS Data Rate 3.0 Gb/s

Models: J610S J310S

1 62
Download 62 pages 43.72 Kb
Page 45
Image 45

Chapter 3: Management

P22

CN2

SAS

3.0G

OK

End

----

Rdy

P23

CN2

SAS

3.0G

OK

End

----

Rdy

Port:Port Id

Type:SAS

Rate:Rate 3G

 

 

Init:Init Passed

Dev:Device Type

Link:Link Connected

 

PRdy:Phy Ready

 

 

 

 

 

 

The following items are reported in the table above:

Link number – The links are PHYs, numbered P0 through P23

Port number – D01 through D16 represent drive slots. Each slot has one PHY. D13 through D16 are empty on J310s units. See “Drive Numbering” on page 19.

CN1 and CN2 represent the external SAS port connectors. Each port has four PHYs. CN1 is labeled with a circle icon. CN2 is labeled with a diamond icon. See Figure 3 on page 33

Drive Type – SAS

Data Rate – 3.0 Gb/s

Device Type End means an end device. Exp means an expansion device

Link Connection – Normally, ---- is displayed. If there is a connection at the moment the link command runs, it will display CONN

Phy Ready Status – If the port is ready, it will display Rdy

Link Counter:

InDW DsEr

DwLo PhRe

CoVi

PhCh

P 0 ---------- ----------

---------- ----------

----------

0x11

P 1 ---------- ----------

---------- ----------

----------

0x61

P 2 ---------- ----------

---------- ----------

----------

0x0D

P 3 ---------- ----------

---------- ----------

----------

0x0D

P 4 ---------- ----------

---------- ----------

----------

0x01

P 5 ---------- ----------

---------- ----------

----------

0x61

P 6 ---------- ----------

---------- ----------

----------

0x11

P 7 ---------- ----------

---------- ----------

----------

0x0D

P 8 ---------- ----------

---------- ----------

----------

0x0D

P 9 ---------- ----------

---------- ----------

----------

0x01

P10 ---------- ----------

---------- ----------

----------

0x0D

P11 ---------- ----------

---------- ----------

----------

0x0D

P12 ---------- ----------

---------- ----------

----------

0x01

P13 ---------- ----------

---------- ----------

----------

0x5D

P14 ---------- ----------

---------- ----------

----------

0x0D

P15 ---------- ----------

---------- ----------

----------

0x09

P16 ---------- ----------

---------- ----------

----------

----

P17 ---------- ----------

---------- ----------

----------

----

P18 ---------- ---------- ---------- ---------- ---------- ----

P19 ---------- ---------- ---------- ---------- ---------- ----

41

Page 45
Image 45
Promise Technology J310S, J610S manual Drive Type SAS Data Rate 3.0 Gb/s